China Zhejiang Ward Electronic Co., Ltd.

 

High Frequency On Line UPS

--
>H SERIES ON LINE UPS 1-3KVA
--
GN SERIES ON LINE UPS 1-3KVA
--
GN SERIES ON LINE UPS 6-20KVA
--
UPS 1KVA ~ 3KVA
--
UPS 6KVA ~ 10KVA
--
UPS 10KVA ~ 20KVA
--
LCD UPS 1KVA ~ 10KVA
--
LCD UPS 10KVA ~ 20KVA

  HPI SERIES INVERTER

--

HPI SERIES INVERTER (500 - 2000VA)


Rack Mount On Line UPS

--
UPS 1KVA-6KVA
--
LCD RM UPS 110V
--
LCD RM UPS 220V

Low Frequency On Line UPS

--
UPS 8KVA ~ 30KVA (1Ph Out)
--
UPS 10KVA ~ 300KVA (3Ph out)

EPS (Emergency Power System)
--
EPS 0.5KW ~ 200KW

ACCESSORY

--

SNMP CARD

--

BATTERY CABINET

Large LCD Display 1KVA ~ 20KVA
Large LCD Display 1KVA ~ 20KVA
• 1KVA ~ 20KVA ( IP/OP:220Vac/230Vac/240Vac )

KEY FEATURES

 True on-line double conversion technology with
 advanced microprocessor control
 Wide input voltage range
Zero transfer time
 Protection against all type of power problems
 Self test while start of the UPS
 Site wiring fault warning
 On-battery power-on function
Smart RS232 communication interface
Intelligent slot available
Sealed lead-acid, maintenance free battery

 


TECHNICAL SPECIFICATIONS

Model   1000T 1000T-XL 200T 2000T-XL 3000T 3000T-XL
Capacity VA/W 1000VA/700W 2000VA/1400W 3000VA/2100W
Input   Base on load percentage (100%-80% / 80%-70% / 70%-80% / 60%-0%)
  Low Line Transfer

160VAC /140VAC /120VAC /110VAC ±5VAC
Low Line Comeback 175VA C ±5VAC
High Line Transfer 300VA C ±5VAC
High Line Comeback 285VA C ±5VAC
Frequency Range 46Hz~54Hz
Phase Single phase with ground
Power Facotr ≥0.95
Output Voltage 220VAC /230VAC /240VAC
  Voltage Regulation ±2%
Frequency(Synchoronized range) 46~54Hz
Frequency(Battery Mode)

50±02Hz
Current Crest Ratio 3:1
Tower Case ≤3% THD(Linear Load) ≤4% THD(Linear Load)
  ≤6% THD(Linear Load) ≤7% THD(Linear Load)
Rack Case ≤4% THD(Linear Load)
  ≤7% THD(Linear Load)
Output Waveform Pure Sinewave
Efficiency To AC Mode 85% 85% 85%
  To Battery Mode 83% 83% 83%
Battery Battery Type 12V/72AH Depending on the capacity of external batteries 12V/72AH Depending on the capacity of external batteries 12V/72AH Depending on the capacity of external batteries
  Numbers of Batteries 3 8 8
  Backup Time(Full Load) > 5 minutes > 9 minutes > 5 minutes
  Recharge Time 5 hours to 90% 5 hours to 90% 5 hours to 90%
  Charging Current(Max.) 1.0A

8A 1.0A 8A 1.0A 8A
  Charging Voltage 41.1Vd ±0.6V 110Vdc ±0.4V
  Battery Type 12V/72AH Depending on the capacity of external batteries 12V/72AH Depending on the capacity of external batteries 12V/72AH Depending on the capacity of external batteries
  Numbers of Batteries 3 8 8
  Backup Time(Full Load) > 5 minutes > 9 minutes > 5 minutes
  Charging Current(Max.) 1.0A 8A 1.0A 8A 1.0A 8A
  Charging Voltage 41.1Vd ±0.6V 110Vdc ±0.4V
Transfer Time AC TO DC
Zero
  Inverter to Bypass
2.5ms(Typical)
Indicator Status
Load Level / Battery Mode / AC Mode / Bypass Mode / Fault
Audible Alram Battery Mode
Sonuding every 4 seconds
  Low Battery
Sonuding every seconds
  Overload
Sonuding twice every seconds
  Fault Confinuousty Sounding
Dimension Tower Case(DxWxH)mm
400x145x220 460x192x340
  UPS Case
482.6x450x87(w.battery ) 482.6x450x87
  Battery Pack 482.6x450x87 482.6x450x87
Weight Tower Case

14 kgs 7 kgs 34.5kgs 15 kgs 35.5 kgs 16 kgs
  Rack Case 16.3 kgs (w.battery ) 10.3 kgs 11.5 kgs 11.2 kgs 12.3 kgs
Environment Operating Temerature 0-40℃
  Relative Humidity 20-90%(NON-CONDENSING)
  Noise Level <45dB@1 Meter <45dB@1 Meter
Interface Smart RS232 Software supports Windows family,Linux,Sun Solaris,IBM Aix,Compaq True64,SGI IRIX,FreeBSD,HP-UX and MAC
  SUMP(option) Power management from SNMP manager and web browse
  USB(option) Windows family and Mac OS

 Please consult the factory or the distributors for further information of "S" models.


 Specifications are subject to change without notice