China Zhejiang Ward Electronic Co., Ltd.

 

High Frequency On Line UPS

--
UPS 1KVA ~ 3KVA
--
UPS 6KVA ~ 10KVA
--
UPS 10KVA ~ 20KVA
--
LCD UPS 1KVA ~ 10KVA
--
LCD UPS 10KVA ~ 20KVA
--
UPS 20KVA ~ 80KVA

Rack Mount On Line UPS

--
UPS 1KVA-6KVA
--
LCD RM UPS 110V
--
LCD RM UPS 220V

 Line Interactive UPS

--
Line Interactive UPS
--
Blazer (Modified Sine Wave Output Waveform)

Low Frequency On Line UPS

--
UPS 8KVA ~ 30KVA (1Ph Out)
--
UPS 10KVA ~ 300KVA (3Ph out)

Electric On Line UPS

--

High Frequency UPS 1KVA ~ 10KVA

--

Low Frequency UPS 10KVA ~ 45KVA


ARRAY UPS

--

Array UPS 4KVA ~ 24KVA (1 Ph Out)

--

Array UPS 15KVA ~120KVA (3 Ph Out)


 EPS (Emergency Power System)

--
EPS 0.5KW ~ 200KW


ACCESSORY

--

SNMP CARD

--

BATTERY CABINET

High frequency On Line ( LCD )
High frequency On Line ( LCD )
• 10KVA ~ 20KVA (  IP/OP:220VAC/380Vac)

KEY FEATURES

 Microprocessor Control Guarantees High Reliability
 Comprehensive Self-Protection Design
 Audible Alarm Mute
 Cold Start Function
 Auto Self-Testing System while Turning On UPS
 Wide Input Voltage Range


TECHNICAL SPECIFICATIONS

MODEL

 

3G10KNDS

3G15KNDS

3G20KNDS

CAPACITY

VA/W

10000VA/7000W

15000VA/10500W

20000VA/14000W

INPUT

Phase

Three Phase with Ground

Frequency Range

46~54Hz

Power Factor

>=0.95

Acceptable Voltage

60~138 Vac

Voltage Range

Line Low Transfer

304VAC +/- 3VAC

Line Low Comeback

322VAC +/- 3VAC

Line High Transfer

478VAC +/- 3VAC

Line High Comeback

361VAC +/- 3VAC

OUTPUT

Phase

Single

Voltage

380VAC/220VAC/230VAC/240VAC

Voltage Regulation

± 1%

Frequency
( Synchronized Range)

46~54Hz

Frequency ( Battery Mode)

50 ± 0.05 Hz

Current Crest Ratio

3:1

Harmonic Distortion

<2% THD ( Linear Load) /
<6% THD ( Non-Linear Load)

Output Waveform

Pure Sinewave

EFFICIENCY

To AC Mode

88%

To Battery Mode

BATTERY

Battery Type

Depending on the capacity of external batteries.

Numbers of Batteries

Backup Time (Full Load)

Recharge Time

Charging Current (Max.)

4.2A

Charging Voltage

274Vdc ± 1%V

TRANSFER TIME

AC to DC

Zero

Inverter to Bypass

Zero

Operation interface

LED Indicator

Normal (green),warning(yellow),Fault(red)

LCD Indicator

Status,Voltage,Frequency,Battery Status,Temperature,History Record,Voltage set

AUDIBLE ALARM

Battery Mode

Sounding every 4 seconds

Low Battery

Sounding every second

Overload

Sounding twice every second

Fault

Continuously Sounding

DIMENSION

UPS Case
D x W x H (mm)

570x260x717

WEIGHT

Net Weight(kgs)

38.5

55

55

ENVIRONMENT

Operating Temperature

0~40 Degrees Centigrade, 20~90% relative humidity (non-condensing)

Noise Level

<60dB @ 1 Meter

INTERFACE

Smart RS-232

Windows 98/NT/2000/XP/2003/ME, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, amd MAC

SNMP (option)

Power management from SNMP manager and web browser

 Please consult the factory or the distributors for further information of "S" models.


 Specifications are subject to change without notice