• 3/3G20KXL~3/3G80KXL (IP/OP:380Vac)
KEY FEATURES
1.Controlled By Twin Microprocessor.
2. Line-Interactive Design. Pure sin wave output.
3. AC startup with no Battery avoid spike when connect batteries.
4. Hot-Swap Batteries.
5. DC-Start mode (cold-start).
6. Voltage Sensitivity adjust button.
7. Three-stage AVR (auto voltage regulation) Auto Buck/Boost mode.
8. Speed Controlled Fan.
9. High Input Voltage Range (145Vac~290Vac).
10. High Input frequency range (66HZ to 44HZ).
11. High Voltage & Overload & Short circuit Protections, RJ-45 surge Protection.
12. Load Level & Battery Level Monitor on Front Panel.
13. LCD panel (optional).
14. Long Backup Time (XL type).
15. True RS232/Dry Contact two way computer interface, RUPS protocol.
16. SNMP Slot (optional), USB interface (optional).
17. Specially designed for PC users, Servers, Workstations, Critical network devices , Data-Center & Telecom equipment ...etc.
18.Bondle Monitor software support Win98/NT/2000/XP & Linux/FreeBSD/Netware.
19. Optional Monitor software support all UNIX system.
■ Functions
Smart Intelligent Battery Management system means longer battery life
Improved reliability results from a precision Smart Battery Charging System, and automatic true-load battery tests. Redundant overcharge protection and continuous, nonplused charging also contribute to longer battery life.
Sine - wave output
A-Smart UPS sine-wave output provides assurance of compatibility with all loads.
Line-interactive design delivers unmatched performance and reliability
Innovative line-interactive design uses the DC to AC power inverter "in reverse" as a battery charger during normal operation providing greater performance, filtering inefficiency. F-ewer components under stress results in greater reliability than inefficient double conversion, on-line UPS units. Line-interactive topology is approximately. 98% efficient, which leads to extremely high reliability. In contrast most online operate at approximately 70% efficiency, which produces life-cycle costs 30% higher. Worse, the excess energy from an on-line UPS becomes heat which damages batteries and decreases reliability.
Line-interactive design delivers Network Interface Port adds automatic safe system shutdown
Once installed, an A-Smart UPS will interface with your network via serial port to perform automated safe shutdown. Power failures can occur at night, on weekends, or while the system administrator is out of the building, which makes automated safe shut-down critical. A-Smart UPS communications port means the ability to coordinate a safe shutdown with most popular operating systems by Novell, IBM, Microsoft, Banyan, UNIX, and others. You can also manage UPS power and diagnose power problems using Upsilon2000 UPS monitor software.
SNMP SLOT adds completely UPS Networks Management
A-Smart UPS includes SNMP Slot that you can Install internal SNMP Card(Optional) for up-rade A-Smart UPS Management of networks.(also can install external SNMP Box via UPS communication port)
ONLINE Hot-Swap user Friendly, Hot swappable battery replacement System
Saves the time and expense of returning the UPS to the factory for Battery service, And allows safe and easy replacement of batteries while your system is up and running. Replacement battery kits ship in a reusable box for convenient return of exhausted batteries to a recycling center or to Netion.
■ Protect
Lightning and surge protection shields hardware
when measured via IEEE 62.41 Category "A" tests, the suppression performance of the A-Smart UPS is superior to virtually all separate surge suppressors.
Network-grade line conditioning prevents glitches
Full time EMI/RFI filters prevent line noise from causing data errors, A-Smart UPS meets Novell and Microsoft's approval for network protection, without the need for additional external conditioners.
Super-Boost automatically corrects brownout conditions
Allows you to work through brownouts without unnecessary battery drain. Super Boost automatically Two-stage up low voltage to safe output levels.
Smart-Back Trim automatically corrects overvoltage conditions
Allows you to work through overvoltages without unnecessary battery drain. Smart-Back Trim automatically steps down high voltage to safe output levels.
■ Messages
Battery Replacement Warning prevents downtime
A-Smart UPS automatically performs a self-test every two weeks. This ensures you will be alerted to degraded batteries before they wear out. Through software, or the push of a button, you may perform self-tests anytime.
Informative LED Display provides status at a glance
Instantly assess the status of your power and the A-Smart UPS without even pushing a button. Bar meters and status indicators are simple to use and easy to understand. Visible and audible alarms alert you to fault conditions.
Load and Battery Meters keep you in control
The Load Meter prevents you from exceeding UPS capacity. The battery Meter reports battery capacity, allowing you to gauge how much time you have before batteries are depleted. An alarm sounds when batteries are low, allowing you time to save data and shutdown the system.
::Diagram of net agent UPS networks monitor::

For UPS Network Monitor completely, you can use Net Agent internal card or external box
Net Agent Feature: 1.provide SNMP MIB to monitor & control UPS 2.Auto-sense 10 Base-T/100M Fast Ethernet 3.Support TCP/IP, UDP, SNMP, Telnet, SNTP,PPP,HTTP,SMTP Protocol 4.Providing easy setup and upgrade tools via MS-Windows, no more traditional RS232 complicated setting nightmare 5.Sending TRAP and E-mail for events notifications simultaneously 6.Auto email daily UPS history report 7.environment Measurement (Optional) 8.External modem dial in/out via PPP protocol (Optional)
::Diagram of net agent use in UPS networks monitor::

■ Spec
Model Name |
A-Smart 1000(XL) |
A-Smart 2000(XL) |
A-Smart 3000(XL) |
A-Smart 6000(XL) |
1KVA |
2KVA |
3KVA |
6KVA |
Input
Voltage
Type |
120Vac |
230Vac |
120Vac |
230Vac |
120Vac |
230Vac |
120Vac |
230Vac |
Allowable
Range |
80~132
Vac |
145~290
Vac |
80~132
Vac |
145~290
Vac |
80~132
Vac |
145~290
Vac |
80~132
Vac |
145~290
Vac |
Input
Protection |
Circuit Breaker |
Circuit Breaker |
Circuit Breaker |
Circuit Breaker |
Boost/Buck
Range |
120Vac 92~103Vac(2 stage)/132~150Vac(1 stage) |
230Vac 184~206Vac(2 stage)/264~300Vac(1 stage) |
Input
Frequency |
50/60Hz(Auto Selectable) |
Transfer
Time |
2~3.5ms(Normal Load) Max:<10ms |
Output
Voltage
(Inverter) |
120V±5% |
230V±5% |
120V±5% |
230V±5% |
120V±5% |
230V±5% |
120V±5% |
230V±5% |
Output
Frequency
(Inverter) |
50/60Hz±0.1Hz |
50/60Hz±0.1Hz |
50/60Hz±0.1Hz |
50/60Hz±0.1Hz |
Output
Waveform
(Inverter) |
Pure sinewave |
Pure sinewave |
Pure sinewave |
Pure sinewave |
Output
Capacity |
1000VA/660W(700W) |
2000VA/1400W |
3000VA/2100W |
6000VA/4200W |
Characteristics |
True Line-Interactive design |
Protections |
High Voltage & Overload & Short Circuit & Low Battery |
Total
Battery
Voltage |
24Vdc/36Vdc/
(48Vac) |
48Vac |
48Vac |
48Vac |
Recharge
Time |
3~8 Hours(24 Hours) |
12 Hours(24 Hours) |
12 Hours(24 Hours) |
18 Hours(24 Hours) |
Backup
Time |
FULL
LOAD |
6/10 min
(2/4/6...hr) |
20min(2.5...hr) |
10min(2...hr) |
12min(2...hr) |
HALF
LOAD |
12/20min
(4/8/12...hr) |
40min(5...hr) |
20min(4...hr) |
25min(4...hr) |
Auto
turn on |
12/20/30min
(2/4/6hr) |
12/20/30min
(2/4/6hr) |
12/20/30min
(2/4/6hr) |
12/20/30min
(2/4/6hr) |
Comm.
Interface |
Ture RS232 / Dry Relay Contact two way |
User
Interface |
LED Display LCD(optional) |
LED
Displays |
Front : Battery Charge, Load Level ,On-Line, Over Load,
Buck, Boost, On-Battery, Battery weak |
Back : Voltage Sensitivity(Generator Mode),Site Fault |
Audible
Sound |
40dBA |
50dBA |
50dBA |
50dBA |
Operating
temperature |
0~40℃ |
0~40℃ |
0~40℃ |
0~40℃ |
Store
temperature |
-15℃ ~ +45℃ |
-15℃ ~ +45℃ |
-15℃ ~ +45℃ |
-15℃ ~ +45℃ |
Surge
Protection
approvals |
IEEE C62.41 CATEGORY A |
Safety
approvals |
UL/TUV |
EMI approvals |
CISPER22 CLASS B FCC CLASS B |
Dimension
(H*W*D)(mm) |
216*170.5*380 |
432*196*546 |
432*196*546 |
432*196*546 |
Net Weight |
18.5Kg(15.5Kg) |
46.8Kg(32Kg) |
50.3Kg(38Kg) |
91.8Kg(71Kg) |
Please consult the factory or the distributors for further information of "S" models.