High Frequency On Line UPS
HPI SERIES INVERTER
Rack Mount On Line UPS
Low Frequency On Line UPS
EPS (Emergency Power System)
ACCESSORY
|
 |
|
[champion UPS, industrial UPS, special UPS]
As a professional manufacturer, exporter, supplier and factory in China.--Zhejiang Ward Electronic Co., Ltd. are a high technology enterprise. Our company most specialized in the study & produce, manufacture & sales various kinds of UPS products, (Uninterrupted Power Systems). Our product's, champion UPS, industrial UPS, special UPS capacity covered 500VA to 120KVA. Our company has obtained the approval of ISO 9001, CE certificate and the Network Access License for Telecommunications Equipment Ministry of information industry, PRC. The On-Line UPS adopted the worldwide latest version software technique and advantage DSP\IGBT power component & high frequency technique.
|
UPS 10KVA ~ 300KVA (3Ph out)
|
| |
WARD GP33 series low frequency on line UPS from 10KVA to 300KVA. It’s designed special for data management center, manufacture industry, petrify system, metallurgical industry, power system etc. It’s adopted twin changing online design, intelligent IGBT module, PWM pulse-width modulation and several CPU, champion UPS, industrial UPS control technology. It’s the best protection equipment for various kinds of important equipments. It can enlarge the capacity up to 8 units UPS use in parallel. champion UPS, industrial UPS, special UPS
FEATURES High Reliable
* Adopt twin change on line technology,sequester extraneous interference
* Favorable overload ability and protection
* Design with 100% unbalance protection
* 100% Non linear load ability
* IGBT, PWM inverter together with digital
logic power control technology
* Industrial grade UPS Super Safety
* The output isolate transformer can avoid the destruction of abnormal signal & lightning stroke
* With static bypass, repair bypass, battery maintain bypass
* Cold start Smart
* Different loading have different use way. Single UPS, 1+1 or N+1 etc.
* Modular design, easy to repair
* Intelligent management for battery pack
Economic
* The efficiency of complete system more than 90%, it will be up to 95% or more if ECO mode
Easy Operation
* LED/LCD display, it’s easy to operate
Intelligent
* It can remote management and TVSS through the offered RS232()RS422, optional SNMP Card, RJ45 etc. communicate port
APPLIANCE
* Data management equipment and system
* Automatic control systems
* Hospital
* Mini office system
* Telecommunication systems
* Bank
|
|
Technical Parameter
Model |
GP3310 |
GP3315 |
GP3320 |
GP3330 |
GP3340 |
GP3360 |
GP3380 |
GP33100 |
GP33120 |
GP33140 |
GP33160 |
GP33200 |
GP33250 |
GP33300 |
Capacity |
10KVA |
15KVA |
20KVA |
30KVA |
40KVA |
60KVA |
80KVA |
100KVA |
120KVA |
140KVA |
160KVA |
200KVA |
250KVA |
300KVA |
Input |
Voltage |
220/380VAC±20% (Three phases +N + G) |
Frequency |
50Hz ± 10% |
Power Factor |
0.8 (0.95 if lagging) |
Bypass |
Phase Qty. |
Three phases 4 wires + G |
Voltage |
380V ± 15% |
Frequency |
50Hz ± 2% |
Output |
Voltage |
380VAC±1% (steady state) |
Frequency |
50Hz±5% (AC Power Mode); 50Hz±0.1%(Battery Mode) |
Power Factor |
0.8 (lagging) |
Wave Form |
Sine Wave |
Distortion |
= 3% (linear load), = 5% (non linear load) |
Transitory Voltage of dynamic load |
±5% (0 ~ 100% Decrease step by step) |
Transitory recover time |
< 10ms (±5%) |
Unbalance Voltage |
< 3%, <1%( balanced load) |
Overload Ability |
150% for 1 minute, 125% for 10 minutes, more than 150% for 200ms |
Crest Factor |
3:1 |
Efficiency |
> 90%, 95% (ECO mode) |
Battery |
Type |
12VDC Sealed lead acid battery, maintenance free |
Nominal Voltage |
384VDC (32PCS) |
396VDC(33PCS) |
Recharge Time |
< 10 hours up to 90% capacity |
Charge Current |
10~25A (Adjustable) |
Transfer time |
0 ms ( AC to DC or DC to AC); < 4 ms (Bypass to Inverter or Inverter to Bypass) |
LCD Display |
UPS work situation, AC power situation, Battery situation, automatic turn to bypass, overload |
Protection |
Over Voltage, Under Voltage, Over Load, Over Temperature, Short Circuit, Lightning Stroke etc. |
Alarm |
Over Temperature, Battery, Bypass, AC Power Abnormal, Over Load, Over Voltage |
Noise ( 1 m distance) |
< 50dB |
< 55dB |
< 65dB |
< 68dB |
Communicate Interface |
RS232 (or RS422), SNMP Card (Optional), RJ45 |
Cooling way |
Fan |
Ambient |
Temperature |
0 ? ~ 40 ? |
Humidity |
10% ~ 90% (no dewfall) |
Elevation |
< 2000m |
Size (mm) |
700×520×1100 |
800×600×1200 |
900×660×1500 |
1250×900×1600 |
2000×900×1800 |
2400×900×1800 |
N.W. (kg) |
210 |
258 |
350 |
400 |
480 |
650 |
900 |
1100 |
1200 |
1250 |
1380 |
1520 |
1650 |
1800 |
EMC |
IEC62040-2, EN50091-2, GB9254 |
Ability of Antijamming |
IEC61000-4 |
Protection Degree |
IP20 |
|
EPS 0.5KW ~ 200KW |
|
Features:
Adopting touching LCD screen and Chinese-display the EPS simulated flow chart
Twin changing online design, adopting the DSP technology and make EPS more protective and dependable.
Flexible parallel technology applies to kinds of laden systems, and its efficiency more than 90%.
The system, special UPS has passed tests for short circuit and 2KVA high voltage insulation strictly.
The isolation of the output transformer reducing the direct interference of waveform current and city electricity. |
| 1 INPUT AND 1 OUTPUT SERIES: EPS TECHOLOGY PARAMETER SHEET |
SPECIFICATION & SIZE |
EPS-0.5KW |
EPS-1KWA |
EPS-2KW |
EPS-4KW |
EPS-5KW |
EPS-1OKW |
EPS-12KW |
EPS-15KW |
EPS20KW |
INPUT |
LINE |
1 PH 2W+G |
VOLTAGE |
150--280VAC |
FREQUENCY |
50HZ± 10% |
OUTPUT |
WAVE SHAPE |
SINE WAVE, THD<3%(BE IN EMERGENT SHAPE); THE SAME WITH MAIN ELECTRICITY(UNDER MAIN ELECTRICITY NORMAL) |
VOLTAGE |
220V±1%(BE IN EMERGENT SHAPE);THE SAME WITH MAIN ELECTRICITY(UNDER MAIN ELECTRICITY NORMAL) |
FREQUENCY |
50HZ±0.5%(BE IN EMERGENT SHAPE); THE SAME WITH MAIN ELECTRICITY(UNDER MAIN ELECTRICITY NORMAL) |
REPLY IN SHORT TIME |
100% LOADED CHANGE, ±4 |
OVER-LOADED CAPACITY |
120% LIMITED CURRENT, RUN NORMALLY |
150% LIMITED CURRENT, STOPPING WORKING AFTER 5S(BE USEFUL IN EMERGENCY |
WAVE AND SUMMIT RATE |
3:01 |
SWITCH TIME |
<100MS |
|
BATTERY QTY |
4 CELLS |
6 CELLS |
BATTERY |
PATTERN |
LEAD ACID BATTERY |
SUPPLY ELECTRICITY TIME |
>90 MINUTES |
SUPPLEMENT ELECTRICITY TIME |
SUPPLEMENT ELECTRICITY TO 90% WITHIN 7~10HOURS |
EFFECIENCY (FULL) |
>80% |
>84% |
|
NOICE |
50DB |
55DB |
|
PROTECTION |
LIMITING CURRENT OUTPUT WHILE OVER-LOAD;RESTRAININNG OHTERS INFO |
CIRCUMSTANCE |
TEMPRETURE |
-30~40°C |
HUMIDITY |
NON-CONDENSE CAN REACH AT 90% |
OUTER SIZE W X H XD mm |
x 600 |
600 x 1400 x 215 |
x 850 |
850 x 1750 x 550 |
x 215 |
900 x 800 x 600, 950 x 820 x 650 |
3 INPUT AND 3 OUTPUT SERIES: EPS TECHOLOGY PAREMETER SHEET
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-160KW |
MOST OUTPUT CURRENT |
28A |
42A |
56A |
85A |
113A |
141A |
169A |
205A |
255A |
304A |
360A |
450A |
WORKING MODE&PRINCIPIUM |
ONLINE POWER SUPPLY STATIC STATE BYPASS SWITH (UNINTERRUTIBLE POWER SWITCH ) TWIN CHANGING TECHNOLOGY COMPLETE INSULATING POWER SUPPLY |
INPUT VOLTAGE |
380VAC±25%(3 INPUT & 3 OUTPUT)+N+G |
FREQUENCY |
50HZ±10%, 60HZ±10% |
OUTPUT VOLTAGE |
380VAC±1% ( load in steady) |
FREQUENCY |
50HZ±0.2%, 60HZ ± 0.2% (SUPPLY POWER FROM BATTERIES) |
WAVE AND SUMMIT RATE |
3:01 |
WAVE DISTORTATION |
LINEARY<3%,NON-LINEARY <5% |
LOADING VOLTAGE CHANGE (FROM 0 TO 100%) |
<±5% |
BATTERIES QUANTITY |
32 CELLS |
33 CELLS |
40 CELLS |
BATTERIES VOLTAGE |
384VDC |
396VDC |
480VDC |
TRANFORMATION TIME |
<100MS |
OVER-LOADED CAPACITY |
125% 10 MIN, 150% 1 MIN |
WORK EFFECIENCY |
93% |
93% |
94% |
94% |
95% |
95% |
95% |
96% |
VOICE DISTANCE 1 METER |
48--60DB |
53--65DB |
COOL WAYS |
COMPULSORY VENTILATION |
|
RELATIVE HUMIDITY(NON-CONDENSE) |
5%--95% |
COMPUTER COMMUNICATION PORT |
RS232 / RS422 |
OUT SIZE (W X H X D mm) |
560 x 1140 x 80 |
560 x 1400 x 800 |
950 x 1800 x 850 |
1200 x 1800 900 |
WEIGHT (kg) |
210 |
258 |
350 |
400 |
480 |
580 |
650 |
900 |
1200 |
1300 |
1350 |
1480 |
|
| |
|
|
|
|