APPLICATION
Servers, Data-centers, Critical network devices, Sensitive electronic equipment, Telecom...
KEY FEATURES
l Large Blue Back LCD for Detailed Real-Time UPS Status Display(GN series)
l Microprocessor control guarantees high reliability
l Equipped with Boost and Buck AVR to stabilize input voltage
l Built-in DC start function enables UPS to started up without AC power supplied
l Smart RS-232 Communication port with Free Downioad Software fromthe Internet
l User-Replaceable Battery Design
l Auto charge while AC recovery
l Provides Modem/Phone line Surge Protection
l Provides Discharge,Overcharge,and Overload Protection
TECHNICAL SPECIFICATIONS
MODEL |
|
G6KN |
G6KNS |
G10KN |
G10KNS |
3G10KN |
3G15KNS |
3G20KNS |
CAPACITY |
VA/W |
16kVA/4.2kW |
10kVA/7kW |
10kVA/7kW |
15kVA/10.5kW |
20kVA/14kW |
INPUT |
Low Line Transfer |
176VAC±3VAC 304VAC±3VAC |
Low Line Comeback |
185VAC±3VAC 322VAC±3VAC |
High Line Transfer |
276VAC±3VAC 478VAC±3VAC |
| High Line Comeback |
266VAC±3VAC 461VAC±3VAC |
Frequency Range |
50Hz: 46~54Hz; 60Hz: 56~64Hz |
| Phase |
Single phase with ground Three phase with ground |
| Power Factor |
≥ 0.98 ≥0.95 |
OUTPUT |
Voltage |
220VAC/230VAC/240VAC |
Voltage Regulation |
±1% |
Frequency |
Synchronization range (line mode); 50 or 60 x (1±0.5%)Hz (Battery mode) |
Current Crest Ratio |
3:1 |
Voltage Distortion |
≤2% THD (Linear Load) ≤6% THD (Non-Linear Load)
|
Output Waveform |
Pure Sinewave |
EFFICIENCY |
|
>82% (1 kVA) >84% (2-3kVA) |
BATTERY |
Battery Type |
12V/7Ah |
|
12V/7Ah |
|
|
|
|
Numbers of Batteries |
20 |
Depending on the capacity of external batteries |
20 |
Depending on the capacity of external batteries |
Depending on the capacity of external batteries
|
Backup Time(Full Load) |
8 minutes |
5 minutes |
| Recharge Time |
7 hours to 90% |
8 hours to 90% |
| Charging Current(Max.) |
2A |
4.2A |
2A |
4.2A |
4.2A |
4.2A |
4.2A |
| Charging Voltage |
274Vdc±1V |
Transfer Time |
AC to DC |
Zero |
Inverter to Bypass |
2.5ms(Typical) |
Indicator |
Status |
Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault |
Audible Alarm |
Battery Mode |
Sounding every 4 seconds |
Low Battery |
Sounding every second |
| Overload |
Sounding twice every second |
| Fault |
Continuously Sounding |
Interface |
Smart RS232 |
Software supports Windows family, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX and MAC |
SNMP(optional) |
Power management from SNMP manager and web browse |
| USB(optional) |
Windows family and Mac OS |
Environment |
Operating Temperature |
0-40℃ |
| Relative Humidity |
20-90%(NON-CONDENSING) |
| Noise Level |
<55dB@1 Meter <60dB@1 Meter |
Physical Feature |
Weight |
90kgs 35kgs 93kgs 38kgs 39kgs 55kgs 55kgs |
Dimensions(H x W x D)mm |
570x260x717 |
Specifications are subject to change without notice
|