| ARRAY is a scalable, modular, flexible solution
that combines the highest level of reliability and availability
in power protection with the lowest costs of ownership, it
is uniquely designed to meet ever-changing commercial &
industrial needs and enables users with an expandable level
of redundancy through standard hot-swappable UPS-module, LCD UPS, LED UPS. ARRAY
4~24kVA, hereinafter called A UPS, is of single phase output
and compatible with either three-phase or single phase mains
input. A UPS is a scalable power protection system in the
range of 4 to 24kVA, this gives you to protect your investment
while enabling your system to grow. It becomes easy and simple
for future power protection demands by adding UPS-module, LCD UPS, LED UPS without
further additional costs and space requirements. Thanks to
the proven on-line, double conversion with static bypass architecture,
each 4kVA UPS-module is a completely independent UPS unit,
this design offers the greatest degree of availability in
power supply with processed power at all times. Designed with
N+X parallel redundancy to provide a fault-tolerant network
of power protection for highest system availability, A UPS
system, LCD UPS, LED UPS provides continuous, high-quality AC power to connected
critical equipment, protecting them against any power disturbances
due to blackouts, brownouts, surges, spikes, lightning and
line noise interference.
APPLICATION
Modular, scalable, network-level redundant power protection
for multiple servers, mid-size datacenters and business-critical
network applications
KEY FEATURES
Highest flexibility
A UPS, LCD UPS, LED UPS is scalable 4 to 24kVA, compatible
with either three-phase or single phase mains input. Its
modular design gives flexible solution to protect your initial
investment in power protection while enabling your system
to grow. It becomes easy and convenient to meet your
future power demands, simply by adding UPS-module in increments
of 4kVA. All modules are hot-swappable, this allows adding
or removing modules while the system is running, without
any interruption to the output.
N+X redundancy
This design enables customers with
an expendable level of redundancy according to their needs.
Users can opt for a greater degree of redundancy with up
to N+5, simply by adding UPS-modules, LCD UPS, LED UPS into the frame without
taking valuable floor space. All UPS-modules are running
in parallel, evenly sharing the connected load, not only
to maximize redundancy, but also system availability.
| Load |
Number of UPS-module |
| 1 unit |
2 units |
3 units |
4 units |
5 units |
6 units |
| 4KVA |
N |
N + 1 |
N + 2 |
N + 3 |
N + 4 |
N + 5 |
| 8KVA |
|
N |
N + 1 |
N + 2 |
N + 3 |
N + 4 |
| 12KVA |
|
|
N |
N + 1 |
N + 2 |
N + 3 |
| 16KVA |
|
|
|
N |
N + 1 |
N + 2 |
| 20KVA |
|
|
|
|
N |
N + 1 |
| 24KVA |
|
|
|
|
|
N |
Highest reliability
With UPS-module containing unique paralleling
control, featuring N+X parallel redundancy, A UPS is to
provide a fault-tolerant power protection for maximum availability,
eliminate downtime and enhance serviceability as well.
Highest availability
The standard UPS-module is a completely
independent UPS unit and adopts the proven double-conversion
online technology with static bypass, all modules in the
frame are hot-swappable. A UPS provides a perfect power
protection against single point-of-failure and ensures maximum
uptime and continuous availability.
Highest simplicity
With its modularity, it
is easy to install and operate the system which features
a user-friendly LCD display and LED indicators on the front
panel. Monitoring and control of the UPS system are just
at your fingertips, LED indicators provide you with the
UPS, LCD UPS, LED UPS working status at a glance.
Highest performance
A UPS with true online double
conversion architecture protects against all kinds of common
power problems, offers scalable, flexible solution in power
protection at the lowest total costs of ownership and
higher operating efficiency.
The near to one input power factor reduces the input installation
costs, high efficiency that means low heat emission is also
good for our environment by using advanced transformer-less
high frequency design.
Longer backup time
This unique feature with generator-friendly meets most
today's requirements for long backup time of high-quality
AC power supply by either choosing in combination of most
generators in the marketplace as a second power source,
or installing appropriate number and the capacity of the
battery groups specific to users' needs to realize for long
time power protection, users may also opt for an extra Charger
module to faster recharge the large capacity of the battery
bank, thereby to maximize availability.
Manageability
The whole A UPS, LCD UPS, LED UPS system can be managed locally and remotely
by means of your computer networks from anywhere.
Local management
The system is provided with a 5x20 character backlit LCD
display and control panel, it puts all the control and monitoring
of the UPS at user's fingertips.
Remote management
A UPS is provided with two communications paths for remote
monitoring, shutdown and management.
TECHNICAL SPECIFICATIONS
|
General |
|
Product |
ARRAY,
A UPS |
|
Power
Capacity |
4
~ 24kVA / 2.8 ~ 16.8kW |
|
Topology |
True
online, double-conversion |
|
Construction |
Modular
(Standard UPS-module of 4kVA) |
|
Redundancy
Capability |
Network-level
N+X redundancy |
|
Bypass |
Automatic
on overload or UPS failure, manual maintenance switch |
|
Input
& output connections |
Ha
rdwired |
|
Standards |
EMS: IEC 61000-4-2 Level 4 (ESD)
IEC 61000-4-3 Level 3 (RS)
IEC 61000-4-4 Level 4 (EFT)
IEC 61000-4-5 Level 4 (Surge)
EMI: IEC62040-2 |
|
Operating Temperature |
0
~ 40 °C |
|
Relative humidity |
20%
~ 90%, non-condensing |
|
Input |
|
Configuration |
3-phase
(3j4w + G) or single phase (1j2w + G) |
|
Input
voltage range |
204
~ 520VAC (3-phase) or 118 ~ 300VAC (single) |
|
Input
Frequency |
46
~ 54/56~64 Hz |
|
Input
Power Factor |
³
0.98 |
|
Output |
|
Configuration |
Single
phase (1j2w + G) |
|
Nominal
Voltage |
220VAC |
|
Output
Voltage Regulation |
±2% |
|
Output
Frequency |
50/60
Hz |
|
Output
Frequency Regulation |
±4Hz
online, ±0.5% on battery |
|
Output
Power Factor |
0.7 |
|
Overload
Capability |
110%
~ 130% for 30 sec, >130% for 2 sec |
|
Load
Crest Ratio |
3:1 |
|
Monitoring
and Control |
|
LED
Indicators |
UPS
status: Normal , On
battery, Bypass, Fault |
|
LCD
Display and Controls |
5
x 20 character backlit LCD display, Programmable |
|
Communications
Port |
RS232,
RS-485, Intelligent slot |
|
Mechanical |
|
Dimensions
of System
Frame |
442
x 700 x 965 mm (W x D x H) |
|
Weight
of System Frame |
75
kg |
|
Weight
of UPS-module |
15
kg each |
|
Dimensions
of Battery
Cabinet |
442
x 700 x 965 mm (W x D x H) |
|
Weight
of Battery Cabinet |
65
kg w/o batteries |
Specifications are subject to change
without notice
|