EPS 0.5KW ~ 200KW
special UPS

Features:

Adopting touching LCD screen and Chinese-display the EPS simulated flow chart
Twin changing online design, adopting the DSP technology and make EPS more protective and dependable.
Flexible parallel technology applies to kinds of laden systems, and its efficiency more than 90%.
The system, special UPS has passed tests for short circuit and 2KVA high voltage insulation strictly.
The isolation of the output transformer reducing the direct interference of waveform current and city electricity. special UPS


1 INPUT AND 1 OUTPUT SERIES: EPS TECHOLOGY PARAMETER SHEET

SPECIFICATION & SIZE

EPS-0.5KW

EPS-1KWA

EPS-2KW

EPS-4KW

EPS-5KW

EPS-1OKW

EPS-12KW

EPS-15KW

EPS20KW

INPUT

LINE

1 PH 2W+G

VOLTAGE

150--280VAC

FREQUENCY

50HZ± 10%

OUTPUT

WAVE SHAPE

SINE WAVE, THD<3%(BE IN EMERGENT SHAPE); THE SAME WITH MAIN ELECTRICITY(UNDER  MAIN ELECTRICITY NORMAL)

VOLTAGE

220V±1%(BE IN EMERGENT SHAPE);THE SAME WITH MAIN ELECTRICITY(UNDER MAIN ELECTRICITY NORMAL)

FREQUENCY

50HZ±0.5%(BE IN EMERGENT SHAPE); THE SAME WITH MAIN ELECTRICITY(UNDER MAIN ELECTRICITY NORMAL)

REPLY IN SHORT TIME

100% LOADED CHANGE, ±4

OVER-LOADED CAPACITY

120% LIMITED CURRENT, RUN NORMALLY

150% LIMITED CURRENT, STOPPING WORKING AFTER 5S(BE USEFUL IN EMERGENCY

WAVE AND SUMMIT RATE

3:01

SWITCH TIME

<100MS

 

BATTERY QTY

4 CELLS

6 CELLS

BATTERY 

PATTERN

LEAD ACID BATTERY

SUPPLY ELECTRICITY TIME

>90 MINUTES

SUPPLEMENT ELECTRICITY TIME

SUPPLEMENT ELECTRICITY TO 90% WITHIN 7~10HOURS

EFFECIENCY (FULL)

>80%

>84%

 

NOICE

50DB

55DB

 

PROTECTION

LIMITING CURRENT OUTPUT WHILE OVER-LOAD;RESTRAININNG OHTERS INFO

CIRCUMSTANCE

TEMPRETURE

 -30~40°C

HUMIDITY

NON-CONDENSE CAN REACH AT 90%

OUTER SIZE W X H XD mm

x 600

600 x 1400 x 215

x 850

850 x 1750 x 550

x 215

900 x 800 x 600, 950 x 820 x 650

3 INPUT AND 3 OUTPUT SERIES: EPS TECHOLOGY PAREMETER SHEET

EPS-15KW

EPS-15KW

EPS-15KW

EPS-15KW

EPS-15KW

EPS-15KW

EPS-15KW

EPS-15KW

EPS-15KW

EPS-15KW

EPS-15KW

EPS-15KW

EPS-160KW

MOST OUTPUT CURRENT

28A

42A

56A

85A

113A

141A

169A

205A

255A

304A

360A

450A

WORKING MODE&PRINCIPIUM

ONLINE POWER SUPPLY STATIC STATE BYPASS SWITH (UNINTERRUTIBLE POWER SWITCH ) TWIN CHANGING TECHNOLOGY COMPLETE INSULATING POWER SUPPLY

INPUT VOLTAGE

380VAC±25%(3 INPUT & 3 OUTPUT)+N+G

FREQUENCY

50HZ±10%, 60HZ±10%

OUTPUT VOLTAGE

380VAC±1% ( load in steady)

FREQUENCY

50HZ±0.2%, 60HZ ± 0.2% (SUPPLY POWER FROM BATTERIES)

WAVE AND SUMMIT RATE

3:01

WAVE DISTORTATION

LINEARY<3%,NON-LINEARY <5%

LOADING VOLTAGE CHANGE (FROM 0 TO 100%)

<±5%

BATTERIES QUANTITY

32 CELLS

33 CELLS

40 CELLS

BATTERIES VOLTAGE

384VDC

396VDC

480VDC

TRANFORMATION TIME

<100MS

OVER-LOADED CAPACITY

125% 10 MIN, 150% 1 MIN

WORK EFFECIENCY

93%

93%

94%

94%

95%

95%

95%

96%

VOICE DISTANCE 1 METER

48--60DB

53--65DB

COOL WAYS

COMPULSORY VENTILATION

 

RELATIVE HUMIDITY(NON-CONDENSE)

5%--95%

COMPUTER COMMUNICATION PORT

RS232 / RS422

OUT SIZE (W X H X D mm)

560 x 1140 x 80

560 x 1400 x 800

950 x 1800 x 850

1200 x 1800 900

WEIGHT (kg)

210

258

350

400

480

580

650

900

1200

1300

1350

1480


UPS