EPS 0.5KW
~ 200KW |
|
Features:
Adopting touching LCD screen and Chinese-display the EPS simulated flow chart
Twin changing online design, adopting the DSP technology
and make EPS more protective and dependable.
Flexible parallel technology applies to kinds of laden systems,
and its efficiency more than 90%.
The system, special UPS has passed tests for short circuit and 2KVA high
voltage insulation strictly.
The isolation of the output transformer reducing the direct
interference of waveform current and city electricity. special UPS
|
| 1 INPUT AND 1 OUTPUT SERIES: EPS TECHOLOGY PARAMETER SHEET |
|
SPECIFICATION & SIZE |
EPS-0.5KW |
EPS-1KWA |
EPS-2KW |
EPS-4KW |
EPS-5KW |
EPS-1OKW |
EPS-12KW |
EPS-15KW |
EPS20KW |
|
INPUT |
LINE |
1 PH 2W+G |
| VOLTAGE |
150--280VAC |
| FREQUENCY |
50HZ± 10% |
|
OUTPUT |
WAVE SHAPE |
SINE WAVE, THD<3%(BE
IN EMERGENT SHAPE); THE SAME WITH MAIN ELECTRICITY(UNDER
MAIN ELECTRICITY NORMAL) |
| VOLTAGE |
220V±1%(BE IN
EMERGENT SHAPE);THE SAME WITH MAIN ELECTRICITY(UNDER
MAIN ELECTRICITY NORMAL) |
| FREQUENCY |
50HZ±0.5%(BE
IN EMERGENT SHAPE); THE SAME WITH MAIN ELECTRICITY(UNDER
MAIN ELECTRICITY NORMAL) |
| REPLY IN SHORT TIME |
100% LOADED CHANGE,
±4 |
| OVER-LOADED CAPACITY |
120% LIMITED CURRENT,
RUN NORMALLY |
150% LIMITED CURRENT,
STOPPING WORKING AFTER 5S(BE USEFUL IN EMERGENCY |
| WAVE AND SUMMIT RATE |
3:01 |
|
SWITCH TIME |
<100MS |
|
|
BATTERY QTY |
4 CELLS |
6 CELLS |
|
BATTERY |
PATTERN |
LEAD ACID BATTERY |
| SUPPLY ELECTRICITY TIME |
>90 MINUTES |
| SUPPLEMENT ELECTRICITY TIME |
SUPPLEMENT ELECTRICITY
TO 90% WITHIN 7~10HOURS |
|
EFFECIENCY (FULL) |
>80% |
>84% |
|
|
NOICE |
50DB |
55DB |
|
|
PROTECTION |
LIMITING CURRENT OUTPUT
WHILE OVER-LOAD;RESTRAININNG OHTERS INFO |
|
CIRCUMSTANCE |
TEMPRETURE |
-30~40°C |
| HUMIDITY |
NON-CONDENSE CAN REACH
AT 90% |
|
OUTER SIZE W X H XD
mm |
x 600 |
600 x 1400 x 215 |
| x 850 |
850 x 1750 x 550 |
| x 215 |
900 x 800 x 600, 950
x 820 x 650 |
|
| 3 INPUT AND 3 OUTPUT SERIES: EPS TECHOLOGY PAREMETER
SHEET |
|
| EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-15KW |
EPS-160KW |
| MOST OUTPUT CURRENT |
28A |
42A |
56A |
85A |
113A |
141A |
169A |
205A |
255A |
304A |
360A |
450A |
|
WORKING MODE&PRINCIPIUM |
ONLINE POWER SUPPLY
STATIC STATE BYPASS SWITH (UNINTERRUTIBLE
POWER SWITCH ) TWIN CHANGING TECHNOLOGY COMPLETE
INSULATING POWER SUPPLY |
|
INPUT VOLTAGE |
380VAC±25%(3
INPUT & 3 OUTPUT)+N+G |
|
FREQUENCY |
50HZ±10%, 60HZ±10% |
|
OUTPUT VOLTAGE |
380VAC±1% ( load
in steady) |
|
FREQUENCY |
50HZ±0.2%, 60HZ ± 0.2% (SUPPLY POWER
FROM BATTERIES) |
|
WAVE AND SUMMIT RATE |
3:01 |
|
WAVE DISTORTATION |
LINEARY<3%,NON-LINEARY
<5% |
|
LOADING VOLTAGE CHANGE
(FROM 0 TO 100%) |
<±5% |
|
BATTERIES QUANTITY |
32 CELLS |
33 CELLS |
40 CELLS |
|
BATTERIES VOLTAGE |
384VDC |
396VDC |
480VDC |
|
TRANFORMATION TIME |
<100MS |
|
OVER-LOADED CAPACITY |
125% 10 MIN, 150%
1 MIN |
|
WORK EFFECIENCY |
93% |
93% |
94% |
94% |
95% |
95% |
95% |
96% |
|
VOICE DISTANCE 1 METER |
48--60DB |
53--65DB |
|
COOL WAYS |
COMPULSORY VENTILATION |
|
|
RELATIVE HUMIDITY(NON-CONDENSE) |
5%--95% |
|
COMPUTER COMMUNICATION
PORT |
RS232 / RS422 |
|
OUT SIZE (W X H X
D mm) |
560 x 1140 x 80 |
560 x 1400 x 800 |
950 x 1800 x 850 |
1200 x 1800 900 |
|
WEIGHT (kg) |
210 |
258 |
350 |
400 |
480 |
580 |
650 |
900 |
1200 |
1300 |
1350 |
1480 |
|
|
|