UPS 1KVA-6KVA |
| |
|
APPLICATION
Servers, Data centers, Critical network devices, Sensitive
electronic equipment, Telecom...
KEY FEATURES
True on-line double conversion technology with advanced
microprocessor control
Wide input voltage range
Zero transfer time
Protection against all type of power problems
Self test while start of the UPS
Site wiring fault warning
On-battery power-on function
Smart RS232 communication interface
Intelligent slot available
Sealed lead-acid, maintenance free battery
TECHNICAL SPECIFICATIONS
|
|
Product
Series |
Rack
Mount 1~6kVA |
|
Model |
G1KR |
G2KR |
G3KR |
G6KR |
|
Rated
Power |
VA/W |
1kVA
/ 0.7kW |
2kVA
/ 1.4kW |
3kVA
/ 2.1kW |
6kVA/4.2kW |
|
Input |
Nominal
Voltage |
220VAC |
|
Voltage
Range |
115
~ 300VAC |
176
~ 276VAC |
|
Frequency
Range |
46
~ 54Hz(default), user adjustable within 40~60Hz |
46
~ 54Hz |
|
Power
Factor |
0.97 |
0.98 |
|
Connection |
IEC320-10A
inlet |
IEC320-16A
inlet |
Terminal
Block |
|
Output |
Voltage |
220VAC
±
2% |
220VAC
±
1% |
|
Frequency |
46~54Hz
or 50Hz ±
0.2Hz (Line mode)
50Hz ±
0.2Hz ( Battery
mode) |
46~54Hz
(Line mode)
50Hz ±
0.05Hz ( Battery
mode) |
|
Waveform |
Sine
Wave |
|
Overload
Capability |
108%~150%
for 30 sec., ³150%
for 300 ms |
105%~130%
for 10 min., ³130%
for 1 min. |
|
Current
Crest Ratio |
3:1 |
|
Bypass |
Automatic
Transfer |
on
overload and UPS failure |
|
Before
UPS Power-on |
Default
“NO”, user adjustable to “YES” |
Yes |
|
Voltage
Range |
80~264VAC
(Default), user adjustable within 80~286VAC |
176
~ 261VAC |
|
Output
Connections |
IEC320
-10A * 4 |
IEC320-10A
* 4 |
IEC320-10A
and
Terminal Block |
IEC320-10A
* 4 and
Terminal Block |
|
Transfer
Time |
0
ms; less than 4 ms from inverter to bypass and vice
versa |
Zero |
|
LED
indicators |
Status |
Load
level / Battery
level,
Battery
,
Utility Power, Inverter, Bypass, Overload, Fault |
|
Audible
Alarm |
Bypass,
On battery mode, Battery
low,
Overload, Fault |
|
Communications |
RS-232
Serial Interface |
|
|
|
Network
Surge Protection |
RJ45
I/O port available for network or Fax/Modem |
|
Environmental |
Operating
Temperature |
0
~ 40°C |
|
Operating
Humidity |
20
~ 90% non-condensing |
|
Main
Unit |
Net
Weight (Kg) |
15.3 |
10.3 |
11.2 |
18.3 |
|
Dimensions
(W x D x H) mm |
482.6
x 450 x 88 (2U) |
482.6
x 600 x 130 (3U) |
|
Battery
Pack |
Type |
Internal
Batteries |
External
Battery
Pack |
|
Nominal
DC Voltage |
36VDC |
96VDC |
240VDC |
|
Backup
Time (Full load) |
5
min |
9
min
(with
1 BP) |
5
min
(with
1 BP) |
7
min
(with
1 BP) |
|
Net
Weight (Kg) |
-- |
25.3 |
58.2 |
|
Dimensions
(W x D x H) mm |
-- |
482.6
x 450 x 88 (2U) |
482.6
x 600 x 130 (3U) |
Notes:
G1KRS, G2KRS, G3KRS & G6KRS for longer Backup time with
additional Battery Packs are available, please consult local
distributors.
Specifications are subject
to change without notice |
|